Samsung V8 Premium Ultrasound System

$74,000.00

V8 - Redefined Imaging Technologies. The Samsung V8 ultrasound system combines excellent imaging quality powered by Crystal Architecture with efficient, streamlined examinations facilitated by Intelligent Assist tools and a reengineered workflow, tailored to meet the demands of today's bustling clinical settings. The sophisticated and ergonomic design underscores Samsung's meticulous craftsmanship, emphasizing comfort and usability as key priorities for your product experience.

Quantity
Last items in stock

V8 - Redefined Imaging Technologies.

The Samsung V8 ultrasound system combines excellent imaging quality powered by Crystal Architecture with efficient, streamlined examinations facilitated by Intelligent Assist tools and a reengineered workflow, tailored to meet the demands of today's bustling clinical settings. The sophisticated and ergonomic design underscores Samsung's meticulous craftsmanship, emphasizing comfort and usability as key priorities for your product experience.

Highlights

Reengineered workf ow for easy and productive process 

Exquisite imaging quality for reliability and confidence

Intelligent Assist tools for efficient examination

Exquisite Image Quality

ShadowHDR - is designed to suppress shadows and enhance the clarity of displayed grayscale images. ShadowHDR selectively applies high-frequency and low-frequency of the ultrasound to identify shadow areas such as fetal head or spine where attenuation occurs.

ClearVision - advanced image processing technology designed to enhance contrast resolution and sharpen tissue interfaces for more confident image assessment. The noise reduction filter enhances the edge contrast and creates sharp 2D images for optimal diagnostic performance. In addition, ClearVision provides application-specific optimization and advanced temporal resolution in live scan mode.

HQ-Vision - compensates for the natural signal distortion as sound propagates through tissue to display maximum pixel sharpness.

HQ-Vision provides clearer images by mitigating the characteristics of ultrasound images that are slightly blurred than the actual vision.

S-FlowTM - a sophisticated color Doppler technology with greater sensitivity, S-Flow can detect low intensity blood flow. It enables accurate diagnosis when blood flow examination is especially difficult. reducing signal noise.

MV-Flow - is an advanced Doppler technology providing detailed documentation of microvascular perfusion into tissues and organs.

LumiFlow - displays a three-dimenstional "like" appearance to 2D color Doppler enhancing spatial comprehension of blood vessels.

Intelligent Assist tools for efficient examination:

S-Shearwave Imaging - allows for the noninvasive assessment of the stiffness for tissue/lesions in various applications such as breast, liver, MSK and prostate. Color-coded elastogram, quantitative measurements, dual or single display option, and user-selectable ROI functions are especially useful for more confident assessment of breast and liver diseases.

Quantitative measurement of liver fat with ultrasound signal

TAI (Tissue Attenuation Imaging) provides quantitative tissue attenuation measurement to assess steatotic liver changes.

TSI (Tissue Scatter distribution Imaging) provides quantitative tissue scatter distribution measurement to assess steatotic liver changes.

Quantify wall motion of the left ventricle 

Strain+ - is a quantitative tool for measuring global and segmental wall motion of the left ventricle (LV). In Strain+, three standard LV views and a Bull's Eye are displayed in a quad screen for easy and quick assessment of the LV function.

NeedleMate+ - dramatically enhances needle visualization when performing commonly used intervention procedures.

QuickSaveTM - is a quantitative tool for global and segmental wall motion of the left ventricle (LV). In Strain+, three standard LV views and a Bull's Eye are displayed in a quad screen for easy and quick assessment of the LV-function.

Analyze selected breast lesions and report breast assessment

S-Detect for Breast - which analyzes selected lesions in the breast ultrasound study and shows the analysis data, applies BI-RADS ATLAS (Breast Imaging-Reporting and Data System, Atlas) to provide standardized reporting; and helps diagnosis with the streamlined workflow.

NerveTrack - is a function that detects and provides information of the location of nerve area in real-time during ultrasound canning.

Transducers

Curved array transducers:

CA3-10A - Abdomen, Obstetrics, Gynecology, Pediatric, Musculoskeletal, Vascular, Urology, Thoracic

CA4-10M - Abdomen, Pediatric, Vascular 

CA1-7S - Abdomen, Obstetrics, Gynecology, Pediatric, Musculoskeletal, Vascular, Urology, Thoracic

Linear array transducers:

LA2-14A -Small parts, Vascular, Abdomen, Pediatric, Thoracic, Musculoskeletal

LA2-9A - Small parts, Vascular, Abdomen, Pediatric, Musculoskeletal

LA4-18A  - Small parts, Vascular, Abdomen, Pediatric, Musculoskeletal

LA3-22AI - Musculoskeletal, Intraoperative 

LA2-9S - Small parts, Vascular, Abdomen, Pediatric, Musculoskeletal

Phased array transducers:

PA1-5A - Cardiac, Vascular, Abdomen, Pediatric, TCD, Thoracic

PA3-8B - Cardiac, Pediatric, Abdomen, Vascular, TCD

PA4-12B- Cardiac, Pediatric, Abdomen, Vascular, TCD

Volume transducers:

EV2-10A - Obstetrics, Gynecology, Urology 

CV1-8A - Abdomen, Obstetrics, Gynecology, Urology

Endocavity transducers:

EA2-11AR - Obstetrics, Gynecology, Urology 

EA2-11AV - Obstetrics, Gynecology, Urology

miniER7 - Urology, Obstetrics, Gynecology

CW transducers:

DP2B - Cardiac, Vascular, TCD 

CW6.0 - Cardiac, Vascular, TCD

TEE transducer:

MMPT3-7 - Cardiac

Samsung-V8

Specific References

Samsung HERA W10 Ultrasound...

HERA, which stands for Hyper-aperture and Enhanced Reconstruction Architecture, represents Samsung's new preeminent ultrasound platform dedicated to delivering stunning images. The HERA platform also provides state-of-the-art ergonomics with a simple yet ingenious design, ensuring satisfaction...

$83,000.00